Hello everyone,
Still working on this 1219 that seems to be getting more misadjusted as I work on it.
I have three settings that need to be adjusted but since they're all related (ie. they seem to have an effect on one another) I don't know which one to adjust first or even how. I do have the service manual and have gone over it several times, and I also have the PDF by that American guy, but that one doesn't go into these adjustments.
The settings that are misadjusted are the locating screw (54 on service manual), the equalising arm (194) and part 212 (the height adjuster for the arm lift piston). I just can't figure out in what order or even how these need to be adjusted.
Before I messed with them the problem was that the arm would not lift in multi-mode (there is an entry in the service manual for that, which is what prompted me to adjust #194... but I should have got the other settings right first!).
I would truly appreciate anyone's help, I don't think I will be able to get this turntable going again without it.
Thanks in advance, rgds.,
Damien